Reverse Osmosis Water System

Reverse Osmosis Water System
Product Details

Reverse Osmosis Water system  

Note: Our company are special in producing reverse osmosis water system. We can supply different styles, such as 2RO+EDI, RO and EDI/2RO. We can also produce according customers require.

Flow Chart for drinking water:


??2.png

RO Introduction:

Reverse osmosis is a kind of membrane separation technology which is developed since the 1980s. It mainly uses the semipermeable membrane permeation principle. A pressure is given to it by a certain way.The anti-natural penetration direction of the force makes the water in thick solution permeate into the thin solution. This method is called reverse osmosis. The reverse osmosis device is composed of reverse osmosis components..

Technical Parameters

Reverse osmosis desalination

>98%

System recovery rate

=70%

Pretreatment output of water

5.5m³/h

1st RO output of water(25?)

11m³/h

Raw water Electrical conductivity

678uS/cm

Finished water Electrical conductivity

< 20uS/cm

Voltage

440v 60Hz

Operation & Control system

Automatic/Manual control system, PLC (Siemens) Touch screen, with automatic control program.

Configuration List:

1.1

Level transmitter(4-20mA Output)

1

SUS304

JINCHEN

1.2

Water pneumatic angle seat valve (f38)

1

SUS304

KEERJIAN

1.3

Outlet valve (manual ball valve) (f38)

1

SUS304

KEERJIAN

1.4

Blow down valve (manual ball valve)  (f38)

1

SUS304

KEERJIAN

1.5

360°Fixed cleaning ball

1

SUS316L

KELIYIN

2

Raw water pump

1

SUS304

Grunfos

2.1

Manual ball valve  (f38)

4

SUS304

KEERJIAN

2.2

Check Valve  (f38)

1

SUS304

KEERJIAN

3

Electric heating single tube plate heat exchange (1 raw water heating; 2 pretreatment pasteurization)

1

SUS304

Hexin

4

Diaphragm pressure gauge

1


BRIGHTY

5

Raw water Conductivity meter

1


CICHENG

6

Temperature Sensor

1


JINGCHENG

7

Dosing device (including dosing bucket)

1



7.1

Dosing pump

1


PULSAFEEDER

7.2

Dosing barrel

1



8

Automatic multi-media filters ?800mm

(Sampling ports)

1

SUS304

HEXIN

8.1

Control valve: pneumatic angle seat valve

5

SUS304

KEERJIAN

8.2

Pneumatic angle seat valve

1

SUS304

KEERJIAN

8.3

Gas washing ball

1

SUS304

KEERJIAN

8.4

Metal tube flow meters

1

SUS304

HENJI

8.5

Media: quartz sand


SUS304


8.6

Diaphragm pressure gauge

2

SUS304

BRIGHTY

8.7

Blow down valve (ball)f38

1

SUS304

KEERJIAN

8.8

Sampling valve

1

SUS304

KEERJIAN

Main components introduction

1.Raw water Tank


??3.png

The drinking water flows into the raw water tank which can cushion the impact on system operation causes by the pipe network water pressure instability. The raw water tank is equipped with: Electric water slowly open valve, pressure transmitter, back outlet, the outlet and exhaust ports and so on.

2.Raw water booster pump


??4.png

The system is equipped with a Raw water booster pump.  The raw water booster pump can be started by automatic /manual according to different requirement.

3.Plate Heat Exchange



??5.png

The plate-type heat exchange before the multi-media filter parallels can periodically pasteurize on the raw water tank, multi-media filters, activated carbon filters and precision filter. It can reduce the biological load of the pretreatment system, restore the adsorption capacity of the activated carbon, and to delay the decay of activated carbon adsorption. The pasteurize will be done once in 2-4 weeks .It will be used to increase the raw water temperature in the winter to ensure the water production systems.

Multi-media filters & activated carbon filter

??6.png

4.1 Multi-media filters work principle

The multi-media filters is filled with refined quartz sand.When the water flows through the filter layer from the top to the bottom, the suspended solids and Gluten particles in the water are adhered to the quartz sand. So raw water turbidity and pollution index is decreased.

When the pressure difference reaches a certain value, the device stops the backwash. The recoil is supplemented by compressed air to make the recoil more thoroughly. Backwash time is about 10 to 15 minutes.

4.2 Activated carbon filter working principle

The water filtered by the multi-media filter flows though the activated charcoal filter layer from the top to the bottom. Then the residual chlorine, organics, colloidal silica, odor, and some heavy metal ions and oxidizing substances in the water are activated by carbon adsorption, so as to achieve water purification purpose, Also the water which flows into the reverse osmosis membrane achieves the requirements.

5.Precision filter

??8.png

Precision filter is deep filter processing equipment. It can partial remove corresponding retention = 5µm suspended solids and effectively reduce turbidity and SDI values. Moreover, It can prevent the high-pressure reverse osmosis membrane element from the damage particles = 5µm damage in the processing of the system.


6.Reverse osmosis device

??9.png

Reverse osmosis water treatment device is a membrane separation technology and equipment. It is the most important equipment in this system. It can not only continuous removal of most of the inorganic ions, but also to remove the water almost all organic matter, bacteria, heat, viruses, and particles. Is one of the world's most advanced pure water technology.

Water pressure is increased by high-pressure pump to the desired working pressure. And then the water be sent into the reverse osmosis unit.

Reverse osmosis water production =15m³ / h . reverse osmosis water is sent to the middle of the tank  as the second grade reverse osmosis water. reverse osmosis water production plant =9m³ / h , second grade reverse osmosis water be sent to EDI devices.

The system is equipped with a set the film member cleaning device. When the film member be contaminated, it can be used to chemical clean.


7. Middle Water Tank

??10.png

Middle water tank is used to store the purified water. It can cushion the impact on system operation causes by the pipe network water pressure instability.


8.EDI device

??11.png

Electrode-ionization(EDI) is a technical which uses ion exchange membrane, ion exchange resins and no chemical regeneration continuous electrical to obtain high purity purified water. Suitable for water quality demanding industries.

EDI has the following advantages:

capable of continuous production of ultra pure water

mixed bed resin does not need to be acid regeneration within the module

Easy operation

ensure watertight

Produced water resistance: =5 MO, water production ? 8m³ / h


9.Control Description

??12.png

General: The system uses programmable logic controller (PLC) control, and is equipped with industrial computer display and operating system. The appropriate level of control at all levels need password to enter which can ensure the safety of the entire system. The system can achieve automatic control and manual control modes of operation. The system is equipped with total control cabinet to display the state of each pump and automatic meter (run / stop status )and the testing data; The system is equipped with alarm display (LEDs) and alarm (buzzer).

Specific instructions:

A) The raw tank level gauge controls the opening and closing of the electric valve. When the water is at high-level, the electric slow valve is closed. When the water is at middle-leave, the electric is opening. When the water is at low level the entire system can not run;

2) High-pressure pump and export are equipped with high / low voltage protection. When the import and export pressure can not satisfy the system settings, the system will not run automatically and the police;

3) an intermediate tank level instrument control the two grade reverse osmosis water production (status / self-loop state).When the system is at high level, the reverse osmosis pretreatment system starts circulating and also the reverse osmosis system starts the circulation status. The water level began to produce at low level since the reverse osmosis system into circulation;

4) EDI water production plant producing water-side set back to the original tank failure, automatically enter the purified water tank after water production qualified.


Pure Water tank 5000L

Configuration list

5000L purified water tank

name

Purified water tank

volume

5000L

type

?

quantity

2

standard

GB150-2011 "steel pressure vessel"
     GB5226.1-2008 "Safety of machinery - Electrical equipment"
     JB / T4709-2007 "welded steel pressure vessel welding procedures"


parameters

origin

quantity

Body of tank

1.construction form

Vertical, feet, head and down the wing, on the head and cylinder welded joint, single-layer structure.




2.main body form

Inner tube: tube diameter × height: f1500 × h1500mm; down butterfly head

3.material

Liner and head 316L

4wall thichness

Inner cylinder: d  = 4mm
     Upper and lower head: d  = 4mm

5.working pressure

liner:=0.25 MPa

6.design pressure

liner:0.3  MPa

7.working temperature

liner:=100?

8.design temperature

liner:125?

9.material

Inner cylinder: d  = 4mm
        Upper and lower head: d  = 4mm

10.roughness

Inner surface polishing Ra=0.4um, the outer surface of the upper and lower head mirror polished, matt body straight;

configuration

1.manhole

Sanitary quick opening: DN400, pressure 0-0.4MPa, Material: 304;

Ningbo hexin

1

cleaning ball

(reflow point)

Quick connection, 360º rotation, material 304 jet cleaning maximum effective radius can reach 2m;

keliying

1

3.air breather

Quick coupler, filter housing: 316L

Ningbo hexin

1

Filter PTFE, filter size 5 "X1, filtration precision 0.2µm

dut

1

4.level sensor

Static pressure level gauge

Ningbo jingcheng

1set

5.security outlet

Rupture Disc

Hua li

1

If you are going to wholesale cheap and high purity reverse osmosis water system from one of the leading China reverse osmosis water system manufacturers and factory, please feel free to contact Pharm-Drugs.

Feedback